RAS Thermal
Datasheet · Type T · Rev. 08

Type T Bare Wire
Copper / Constantan

Solid single-strand Type T wire (Copper/Constantan), φ0.025mm to φ5.0mm. The most accurate base-metal pair below zero.

Solid single strand — choose Stranded Wire if the run flexes or vibrates.

Technical Specifications

Property Specification
Positive Leg Copper (Cu 99.9%)
Negative Leg Constantan (CuNi 55/45)
Temperature Range −200°C to +350°C
Diameter Range φ0.025-5.0 mm
Diameter Tolerance ±0.005mm (fine) / ±0.02mm (standard)
EMF Tolerance ±0.5°C (−40-125°C) / ±0.4% (125-350°C)
Standards IEC 60584-1 Class 1 / ASTM E230 / DIN EN 60584
Surface Finish Bright / Oxidized / Electro-polished
Condition Hard (cold-drawn) / Soft (annealed) / Bright finished
Packaging DIN 125 / 160 / 250 / 355 spool / Coil / Custom reel
Coil Weight 5kg / 10kg / 20kg standard
Minimum Order 5 kg per diameter per type
Lead Time 3-5 business days (stock 0.1-3.0 mm) · 2-3 weeks (non-stock) · 4-6 weeks (custom alloy)
Testing & Traceability 100% eddy-current + resistance + dimensional · MTC · EMF calibration certificate · Furnace batch traceability

How to specify Type T Bare Wire

  1. Fix the peak temperature and the atmosphere first: a solid T conductor is the default in air.
  2. Take the diameter and the tolerance class from the table above — they set both the response time and the price.
  3. State the temper, the surface finish, the packaging and how deep the certification has to go, then send it to us.

Frequently Asked Questions (FAQ)

Why is Type T chosen for cryogenic measurement?

Accuracy below zero, for one: ±0.5 °C, the best of any base-metal type down there. The copper leg also resists corrosion in moist environments, so condensation on the wire is not a failure mode.

What is the maximum temperature for Type T?

+350 °C. The copper positive leg oxidises above that. Whatever the nominal −200 °C to +350 °C range suggests, Type T is fundamentally a low-temperature thermocouple.

What diameters does Type T bare wire come in?

φ0.025 mm to φ5.0 mm, supplied to IEC 60584-1 Class 1 / ASTM E230 with MTC and furnace batch traceability.

You may also need

Bottom line: Type T Bare Wire to IEC 60584-1 Class 1, with the MTC and EMF calibration certificate per coil.

Add RAS Thermal as a preferred source on Google