RAS Thermal
Datasheet · Type N · Rev. 08

Type N Bare Wire
Nicrosil / Nisil

Solid single-strand Type N wire (Nicrosil/Nisil), φ0.025mm to φ5.0mm. Built for long service where drift matters.

Solid single strand — choose Stranded Wire if the run flexes or vibrates.

Technical Specifications

Property Specification
Positive Leg Nicrosil (NiCrSi 84.4/14.2/1.4)
Negative Leg Nisil (NiSiMg 95.4/4.4/0.15)
Temperature Range −270°C to +1300°C
Diameter Range φ0.025-5.0 mm
Diameter Tolerance ±0.005mm (fine) / ±0.02mm (standard)
EMF Tolerance ±1.5°C (0-375°C) / ±0.4% (375-1000°C)
Standards IEC 60584-1 Class 1 / ASTM E230 / DIN EN 60584
Surface Finish Bright / Oxidized / Electro-polished
Condition Hard (cold-drawn) / Soft (annealed) / Bright finished
Packaging DIN 125 / 160 / 250 / 355 spool / Coil / Custom reel
Coil Weight 5kg / 10kg / 20kg standard
Minimum Order 5 kg per diameter per type
Lead Time 3-5 business days (stock 0.1-3.0 mm) · 2-3 weeks (non-stock) · 4-6 weeks (custom alloy)
Testing & Traceability 100% eddy-current + resistance + dimensional · MTC · EMF calibration certificate · Furnace batch traceability

How to specify Type N Bare Wire

  1. Fix the peak temperature and the atmosphere first: a solid N conductor is the default in air.
  2. Take the diameter and the tolerance class from the table above — they set both the response time and the price.
  3. State the temper, the surface finish, the packaging and how deep the certification has to go, then send it to us.

Frequently Asked Questions (FAQ)

What makes Type N more stable than Type K above 1000 °C?

The Nicrosil positive leg (NiCrSi 84.4/14.2/1.4) carries 1.4% silicon. That silicon forms a protective SiO₂ sub-layer and suppresses the chromium oxidation behind green rot. Measured result: drift stays within ±1 °C after 500 h at 1000 °C.

What temperature range and diameters does Type N bare wire cover?

−270 °C to +1300 °C, in diameters from φ0.025 mm to φ5.0 mm.

Where is Type N bare wire specified?

Vacuum furnaces, aerospace pyrometry to AMS 2750, gas turbine exhaust monitoring and semiconductor processes. The common thread: sensor replacement is costly, and drift over a long service interval is the enemy.

You may also need

Bottom line: Type N Bare Wire to IEC 60584-1 Class 1, with the MTC and EMF calibration certificate per coil.

Add RAS Thermal as a preferred source on Google