Datasheet · Type N · Rev. 08 Type N Bare Wire
Type N Bare Wire
Nicrosil / Nisil
Solid single-strand Type N wire (Nicrosil/Nisil), φ0.025mm to φ5.0mm. Built for long service where drift matters.
Solid single strand — choose Stranded Wire if the run flexes or vibrates.
Technical Specifications
| Property | Specification |
|---|---|
| Positive Leg | Nicrosil (NiCrSi 84.4/14.2/1.4) |
| Negative Leg | Nisil (NiSiMg 95.4/4.4/0.15) |
| Temperature Range | −270°C to +1300°C |
| Diameter Range | φ0.025-5.0 mm |
| Diameter Tolerance | ±0.005mm (fine) / ±0.02mm (standard) |
| EMF Tolerance | ±1.5°C (0-375°C) / ±0.4% (375-1000°C) |
| Standards | IEC 60584-1 Class 1 / ASTM E230 / DIN EN 60584 |
| Surface Finish | Bright / Oxidized / Electro-polished |
| Condition | Hard (cold-drawn) / Soft (annealed) / Bright finished |
| Packaging | DIN 125 / 160 / 250 / 355 spool / Coil / Custom reel |
| Coil Weight | 5kg / 10kg / 20kg standard |
| Minimum Order | 5 kg per diameter per type |
| Lead Time | 3-5 business days (stock 0.1-3.0 mm) · 2-3 weeks (non-stock) · 4-6 weeks (custom alloy) |
| Testing & Traceability | 100% eddy-current + resistance + dimensional · MTC · EMF calibration certificate · Furnace batch traceability |
How to specify Type N Bare Wire
- Fix the peak temperature and the atmosphere first: a solid N conductor is the default in air.
- Take the diameter and the tolerance class from the table above — they set both the response time and the price.
- State the temper, the surface finish, the packaging and how deep the certification has to go, then send it to us.
Frequently Asked Questions (FAQ)
What makes Type N more stable than Type K above 1000 °C?
The Nicrosil positive leg (NiCrSi 84.4/14.2/1.4) carries 1.4% silicon. That silicon forms a protective SiO₂ sub-layer and suppresses the chromium oxidation behind green rot. Measured result: drift stays within ±1 °C after 500 h at 1000 °C.
What temperature range and diameters does Type N bare wire cover?
−270 °C to +1300 °C, in diameters from φ0.025 mm to φ5.0 mm.
Where is Type N bare wire specified?
Vacuum furnaces, aerospace pyrometry to AMS 2750, gas turbine exhaust monitoring and semiconductor processes. The common thread: sensor replacement is costly, and drift over a long service interval is the enemy.
You may also need
Bottom line: Type N Bare Wire to IEC 60584-1 Class 1, with the MTC and EMF calibration certificate per coil.