The pick for reducing or vacuum service above 800 °C, where Type K green-rots.
What is Type N Thermocouple Wire?
Type N Thermocouple Wire is a base-metal thermocouple conductor pair, Nicrosil (NiCrSi 84.4/14.2/1.4) as the positive leg and Nisil (NiSiMg 95.4/4.4/0.15) as the negative leg, rated −270 … +1300 °C with an EMF tolerance of ±1.5°C (0-375°C) / ±0.4% (375-1000°C).
Author: RAS Thermal Engineering Team
Superior oxidation resistance vs Type K. No green-rot phenomenon. Longer service life in vacuum and inert atmospheres. Lower drift rate above 1000°C.
Slightly higher cost than Type K. Less established EMF reference data compared to Type K.
Compare all 5 types, ranges and tolerances →
Suitable markets: aerospace, laboratories, precision sensors and others
Technical Specifications
| Property | Specification |
|---|---|
| Diameter Range | φ0.025-5.0 mm |
| Tolerance | ±0.005mm (fine) / ±0.02mm (standard) |
| Temperature Range | −270 … +1300 °C |
| Standards | IEC 60584-1 Class 1 / ASTM E230 / DIN EN 60584 |
| Grade Designation | NCHW-1 / NCHW-2 (positive) / VNX (negative) |
| Resistivity | NCHW-1 1.13 ±0.05 · NCHW-2 1.14 ±0.05 μΩ·m |
| Tensile Strength | NCHW-1 / NCHW-2 ≥650 N/mm² · VNX ≥390 N/mm² |
| Elongation | ≥20% |
| Typical Batch Test Data | NCHW-2 1.0 mm, 2025-03-23: ρ 1.14/1.12 μΩ·m, 721/745 N/mm². VNX 1.0 mm, 2026-01-25: 468/454 N/mm² |
| Surface Finish | Bright / Oxidised / Electro-polished |
| Packaging | DIN 125 / 160 / 250 / 355 spool / Coil / Custom reel |
| Coil Weight | 5kg / 10kg / 20kg standard or request |
| Traceability | Furnace batch number engraved on spool |
| Minimum Order | 5 kg bare wire · 10 kg stranded |
| Lead Time | 3-5 business days (stock 0.1-3.0 mm) · 2-3 weeks (non-stock) · 4-6 weeks (custom alloy) |
Available Product Forms
Bare Wire →
Solid single-strand, φ0.025-5.0 mm, bright or oxidised.
Stranded Wire →
Multi-strand for flexibility and vibration resistance. 7/19/37 strand.
How to specify Type N Thermocouple Wire
- Match the atmosphere and the expected continuous temperature to the limitation above before the type is fixed.
- Pick the form, Bare Wire or Stranded Wire, then read the conductor diameter and tolerance class off the specification table.
- Quote against IEC 60584-1 Class 1 and ask for the material test certificate carrying the furnace batch number.
Frequently Asked Questions (FAQ)
How does Type N differ from Type K at high temperature?
The Nicrosil positive leg (NiCrSi 84.4/14.2/1.4) carries 1.4% silicon, which forms a protective SiO₂ layer and suppresses the chromium oxidation behind green rot. Type N drift stays within ±1 °C after 500 h at 1000 °C.
What temperature range does Type N cover?
−270 °C to +1300 °C, with EMF tolerance ±1.5 °C (0-375 °C) / ±0.4% (375-1000 °C) to IEC 60584-1 Class 1.
Where is Type N specified instead of Type K?
Vacuum furnaces, aerospace pyrometry to AMS 2750, gas turbine exhaust monitoring and semiconductor processes, anywhere that sensor replacement is costly or long-interval drift matters.
What is the trade-off of choosing Type N?
A slightly higher cost than Type K and a smaller body of published EMF reference data. Both are supplied to the same standards, so instrumentation support is the main consideration.
Bottom line: Type N is the pick above 1000 °C or wherever the atmosphere is vacuum or reducing: the 1.4% silicon in Nicrosil suppresses green rot and holds drift within ±1 °C after 500 h at 1000 °C. The premium over Type K is usually recovered the first time an unplanned shutdown is avoided.
References & Evidence
- IEC 60584-1:2013: Thermocouples, Part 1: EMF specifications and tolerances ↗
- ASTM E230/E230M: Temperature-Electromotive Force tables for standardized thermocouples ↗
- NIST ITS-90 Thermocouple Database: Type N reference table (SRD 60) ↗
- NIST ITS-90 Thermocouple Database: reference functions and downloadable tables (SRD 60) ↗
- NIST Monograph 175: Temperature-Electromotive Force Reference Functions and Tables ↗
- BIPM SI Brochure: definition of the kelvin and traceability of ITS-90 ↗