Thermocouple Stranded Wire
Stranded thermocouple wire is the multi-strand twisted form of the same five standard alloy pairs, built as 7, 19 or 37 strand constructions from φ0.1 mm to φ5.0 mm. Each product page below carries the full specification table, alloy designation, EMF tolerance and the certification scope you get with the batch.
- KType K, Chromel / Alumel−200 … +1370 °C
- NType N, Nicrosil / Nisil−270 … +1300 °C
- JType J, Iron / Constantan−40 … +750 °C
- TType T, Copper / Constantan−200 … +350 °C
- EType E, Chromel / Constantan−200 … +900 °C
Specifying a stranded wire conductor
Choose stranded wire whenever the conductor moves. Vibration, flexing and repeated thermal cycling work-harden a solid conductor until it fractures at the junction or along the run, a 7, 19 or 37 strand construction distributes that strain across the individual strands instead. It is the correct form for moving parts, vibrating equipment, tight routing radii and any installation where the wire is handled or repositioned during maintenance.
- Confirm the alloy pair and the temperature range for your process, the five standard types covered here are K, N, J, T and E.
- Pick the strand configuration (7, 19 or 37) and the finished conductor diameter from φ0.1 mm to φ5.0 mm.
- Set the temper and finish, annealed tempers are usual where the multi-strand conductor has to flex in service.
Stranded wire supply details
- Construction
- 7 / 19 / 37 strand construction
- Diameter range
- φ0.1 mm, φ5.0 mm, starts at φ0.1 mm because strand lay sets a practical floor on the finished conductor diameter, below that the individual strands are too fine to twist reliably.
- Surface finish
- Bright / Oxidized / Electro-polished
- Condition
- Hard (cold-drawn) / Soft (annealed) / Bright finished
- Packaging
- DIN 125 / 160 / 250 / 355 spool / Coil / Custom reel
Stranded wire or bare wire?
Bare and stranded wire are made from the same five alloy pairs to the same IEC 60584-1 Class 1 and ASTM E230 tolerances. The difference is the conductor construction, and that is what decides which form suits an installation.
| Aspect | Stranded Wire | Bare Wire |
|---|---|---|
| Conductor construction | 7 / 19 / 37 twisted strands | Solid single strand |
| Diameter range | φ0.1 mm, φ5.0 mm | φ0.025 mm, φ5.0 mm |
| Best suited to | Moving, flexing or vibrating conductors | Fixed sensing points and ultra-fine gauge junctions |
Every conductor ships with a mill test certificate, EMF calibration certificate and furnace batch traceability. Tell us the alloy, diameter, finish, temper and coil weight and we return a priced offer.